Gas detector are part of the new gas detector range for industrial and tertiary application. The detector has a head with a sensitive semiconductor element to measure explosive gas
concentration on LEL (Low Explosive Limit) scale.
The detector is pre-set on Prewarning level of 15% and Warning at 30% of LEL. For toxicity NH3 100 ppm prewarning and 200 ppm warning cod 07 and 1000 ppm prewarning and 2000 pmm warning cod 08. A handheld programmer and a PC software are optionally available; with them it is possible to conduct a field test of the detector and to change the configuration:
detection treshold, alarm filters, addressing, full scale, etc. Head replacement can be done only by manufacturer.
The detector is supplied with explosion-proof metal case unit with ATEX II 2G Ex-d IIC T6 certification for the location of the electronic communication and of the sensitive element, that is
placed into the lower part and protected by a sintered filter in resined steel enclosure.